Split Phase Inverter Data
The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "Kumaraguru Prabakar",
"@type": "vcard:Contact",
"hasEmail": "mailto:Kumaraguru.Prabakar@nrel.gov"
}
|
| dataQuality |
true
|
| description | The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "This file contains the dataset for changes in frequency (controllable AC source) .
",
"format": "
",
"accessURL": "https://data.nrel.gov/system/files/213/frequencyrun-1679509305.csv",
"mediaType": "application/octet-stream",
"description": "This file contains the dataset for changes in frequency (controllable AC source) .
"
},
{
"@type": "dcat:Distribution",
"title": "This file contains the experimental data from voltage magnitude step change (controllable AC source).",
"accessURL": "https://data.nrel.gov/system/files/213/voltagerun-1679509305.csv",
"mediaType": "application/octet-stream",
"description": "This file contains the experimental data from voltage magnitude step change (controllable AC source)."
}
]
|
| identifier | https://data.openei.org/submissions/8264 |
| issued | 2023-03-23T16:58:28Z |
| keyword |
[
"PV inverter",
"artificial intelligence",
"data analysis",
"data visualizations",
"database for artificial intelligence training",
"database for inverter characterization",
"database for model validation",
"machine learning",
"pytorch",
"reinforcement learning",
"scikit-learn",
"split phase inverter",
"tensorflow"
]
|
| landingPage | https://data.nrel.gov/submissions/213 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2025-01-17T20:56:09Z |
| programCode |
[
"019:000",
"019:023"
]
|
| projectNumber | CPS agreement number - 38455 |
| projectTitle | Scalable Multi-Timescale Analysis Platform Based on System Transient and Dynamic Models |
| publisher |
{
"name": "National Renewable Energy Laboratory",
"@type": "org:Organization"
}
|
| title | Split Phase Inverter Data |