Skip to main content
U.S. flag

An official website of the United States government

This site is currently in beta, and your feedback is helping shape its ongoing development.

Clinical evaluation of the Life Support for Trauma and Transport (LSTAT) platform

Published by National Institutes of Health | U.S. Department of Health & Human Services | Metadata Last Checked: September 07, 2025 | Last Modified: 2025-09-06
Introduction The Life Support for Trauma and Transport (LSTAT™) is a self-contained, stretcher-based miniature intensive care unit designed by the United States Army to provide care for critically injured patients during transport and in remote settings where resources are limited. The LSTAT contains conventional medical equipment that has been integrated into one platform and reduced in size to fit within the dimensional envelope of a North Atlantic Treaty Organization (NATO) stretcher. This study evaluated the clinical utility of the LSTAT in simulated and real clinical environments. Our hypothesis was that the LSTAT would be equivalent to conventional equipment in detecting and treating life-threatening problems. Methods Thirty-one anesthesiologists and recovery room nurses compared the LSTAT with conventional monitors while managing four simulated critical events. The time required to reach a diagnosis and treatment was recorded for each simulation. Subsequently, 10 consenting adult patients were placed on the LSTAT after surgery for postoperative care in the recovery room. Questionnaires about aspects of LSTAT functionality were completed by nine nurses who cared for the patients placed on the LSTAT. Results In all of the simulations, there was no clinically significant difference in the time to diagnosis or treatment between the LSTAT and conventional equipment. All clinicians reported that they were able to manage the simulated patients properly with the LSTAT. Nursing staff reported that the LSTAT provided adequate equipment to care for the patients monitored during recovery from surgery and were able to detect critical changes in vital signs in a timely manner. Discussion Preliminary evaluation of the LSTAT in simulated and postoperative environments demonstrated that the LSTAT provided appropriate equipment to detect and manage critical events in patient care. Further work in assessing LSTAT functionality in a higher-acuity environment is warranted.

Find Related Datasets

Click any tag below to search for similar datasets

data.gov

An official website of the GSA's Technology Transformation Services

Looking for U.S. government information and services?
Visit USA.gov