Comparisons from an Aqualog Fluorometer Standardized to Quinine Sulfate Equivalents (QSE) with Excitation (ex) and Emissions (em) Equivalent to Fluorescence of Dissolved Organic Matter (fDOM) Sensors from Multiple Manufacturers
Here, we present the results supporting Table 2 in Field Techniques for Fluorescence Measurements Targeting Dissolved Organic Matter, Hydrocarbons, and Wastewater in Environmental Waters: Principles and Guidelines for Instrument Selection, Operation and Maintenance, Quality Assurance, and Data Reporting. Table 2 shows comparisons from an Aqualog 800 benchtop fluorometer standardized to quinine sulfate equivalents (QSE) with excitation (ex) and emissions (em) equivalent to fluorescence of dissolved organic matter (fDOM) sensors from multiple manufacturers. Data are reported from two standard reference materials (SRM) and the mean, minimum, and maximum from 76 environmental samples. No replicates were collected for environmental samples; therefore, the relative standard deviation is not available.
Complete Metadata
| accessLevel | public |
|---|---|
| bureauCode |
[
"010:12"
]
|
| contactPoint |
{
"fn": "Jacob A Fleck",
"@type": "vcard:Contact",
"hasEmail": "mailto:jafleck@usgs.gov"
}
|
| description | Here, we present the results supporting Table 2 in Field Techniques for Fluorescence Measurements Targeting Dissolved Organic Matter, Hydrocarbons, and Wastewater in Environmental Waters: Principles and Guidelines for Instrument Selection, Operation and Maintenance, Quality Assurance, and Data Reporting. Table 2 shows comparisons from an Aqualog 800 benchtop fluorometer standardized to quinine sulfate equivalents (QSE) with excitation (ex) and emissions (em) equivalent to fluorescence of dissolved organic matter (fDOM) sensors from multiple manufacturers. Data are reported from two standard reference materials (SRM) and the mean, minimum, and maximum from 76 environmental samples. No replicates were collected for environmental samples; therefore, the relative standard deviation is not available. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Digital Data",
"format": "XML",
"accessURL": "https://doi.org/10.5066/P9VJUCTP",
"mediaType": "application/http",
"description": "Landing page for access to the data"
},
{
"@type": "dcat:Distribution",
"title": "Original Metadata",
"format": "XML",
"mediaType": "text/xml",
"description": "The metadata original format",
"downloadURL": "https://data.usgs.gov/datacatalog/metadata/USGS.6376842dd34ed907bf6d87c9.xml"
}
]
|
| identifier | http://datainventory.doi.gov/id/dataset/USGS_6376842dd34ed907bf6d87c9 |
| keyword |
[
"California",
"California Water Science Center",
"DOC",
"Organic Matter Research Laboratory",
"Sacramento",
"USGS:6376842dd34ed907bf6d87c9",
"continuous monitoring",
"dissolved organic carbon",
"environment",
"fDOM",
"fluorescence",
"high frequency",
"in situ",
"inlandWaters",
"optical sensor",
"organic matter",
"standard solution",
"water quality"
]
|
| modified | 2022-12-15T00:00:00Z |
| publisher |
{
"name": "U.S. Geological Survey",
"@type": "org:Organization"
}
|
| spatial | -121.8549, 38.1950, -121.0693, 38.9423 |
| theme |
[
"Geospatial"
]
|
| title | Comparisons from an Aqualog Fluorometer Standardized to Quinine Sulfate Equivalents (QSE) with Excitation (ex) and Emissions (em) Equivalent to Fluorescence of Dissolved Organic Matter (fDOM) Sensors from Multiple Manufacturers |