Dynamic Range by Design in OTA EVM measurements
We present an experimental approach to design an over-the-air (OTA) millimeter-wave system for measuring error vector magnitude (EVM) with associated uncertainties that include correlations and nonlinearities. Our approach uses a variable waveguide attenuator at the output of a modulated-signal source at 44 GHz and provides traceable measurements on a calibrated equivalent-time sampling oscilloscope. The conductor-based EVM measurements and associated uncertainties presented here serve as a baseline for the eventual OTA-based EVM. We also discuss a noise based EVM estimation technique as a simple tool for planning OTA EVM measurements, but without a complete knowledge of measurement uncertainties.
Complete Metadata
| bureauCode |
[ "006:55" ] |
|---|---|
| identifier | ark:/88434/mds2-2938 |
| issued | 2024-01-03 |
| landingPage | https://data.nist.gov/od/id/mds2-2938 |
| language |
[ "en" ] |
| programCode |
[ "006:045" ] |
| theme |
[ "Advanced Communications:Wireless (RF)" ] |