Return to search results
EGS Collab Experiment 1: Circulation Testing
These data and test descriptions comprise a chilled circulation test conducted at the 164' fracture in the EGS Collab Experiment 1 testbed on the 4850 ft level of the Sanford Underground Research Facility. Descriptions of the meta data, design drawings for the flow testing system, and evaluation of the thermistor data are provided here. The test ran from April 2019 through early March of 2020, when testing was concluded at the experiment 1 site. These data are are complementary to the stimulation data provided in another submission which is linked below (i.e. stimulation at the 164' notch). More information about the test itself as well as the rationale and process of data processing is available on the EGS Collab Experiment 1 Long Term Circulation Test wiki page which is also linked below.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "Hunter Knox",
"@type": "vcard:Contact",
"hasEmail": "mailto:hunter.knox@pnnl.gov"
}
|
| dataQuality |
true
|
| description | These data and test descriptions comprise a chilled circulation test conducted at the 164' fracture in the EGS Collab Experiment 1 testbed on the 4850 ft level of the Sanford Underground Research Facility. Descriptions of the meta data, design drawings for the flow testing system, and evaluation of the thermistor data are provided here. The test ran from April 2019 through early March of 2020, when testing was concluded at the experiment 1 site. These data are are complementary to the stimulation data provided in another submission which is linked below (i.e. stimulation at the 164' notch). More information about the test itself as well as the rationale and process of data processing is available on the EGS Collab Experiment 1 Long Term Circulation Test wiki page which is also linked below. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Raw Data Files.zip",
"format": "zip",
"accessURL": "https://gdr.openei.org/files/1254/DataFiles.zip",
"mediaType": "application/zip",
"description": "Individual CSV files containing the raw data streams in 1-s or 10-s intervals. Nominal use of the channels are explained in “SensorDescriptions.xlsx”. "
},
{
"@type": "dcat:Distribution",
"title": "EGS Collab Experiment 1 Injection and Production Well Thermistors.pptx",
"format": "pptx",
"accessURL": "https://gdr.openei.org/files/1254/EGS%20Collab%20Experiment_1%20Injection%20and%20Production%20Well%20Thermistors%20.pptx",
"mediaType": "application/vnd.openxmlformats-officedocument.presentationml.presentation",
"description": "A memo on the design, installation and calibration of thermistors used to measure temperature of injection and produced water. Note that these are the new, improved sensors used to replace the faulty sensors in late 2019. See submission 1301 for further discussion."
},
{
"@type": "dcat:Distribution",
"title": "Flow System Field Performance.docx",
"format": "docx",
"accessURL": "https://gdr.openei.org/files/1254/FlowSystemFieldPerformance.docx",
"mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
"description": "A nuanced description of the flow collection system. Includes diagrams and explanations of flow collection systems."
},
{
"@type": "dcat:Distribution",
"title": "Flow Testing Schematic LS for DAQ.pdf",
"format": "pdf",
"accessURL": "https://gdr.openei.org/files/1254/FlowTestingSchematic.LSforDAQ.pdf",
"mediaType": "application/pdf",
"description": "Design diagram of the stim-and-flow system used to collect the raw data."
},
{
"@type": "dcat:Distribution",
"title": "Major Event Log - Long Term Circulation.docx",
"format": "docx",
"accessURL": "https://gdr.openei.org/files/1254/MajorEventLog_LongTermCirculation.docx",
"mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
"description": "A summary of major events during the long-term circulation experiment. A more complete description of the events is available in the form of daily shift reports, available as wiki pages in the "EGS Collab Shift Reports" resource link. "
},
{
"@type": "dcat:Distribution",
"title": "Sensor Descriptions.xlsx",
"format": "xlsx",
"accessURL": "https://gdr.openei.org/files/1254/SensorDescriptions.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "Nominal functions of all the channels in the raw CSV files. Note that occasionally the quantity each channel measured was adjusted and this table is not 100% accurate. Important data have been processed, cleaned, and shared through submission 1301: EGS Collab Circulation Testing Processed Data."
},
{
"@type": "dcat:Distribution",
"title": "ThermistorPerformance.docx",
"format": "docx",
"accessURL": "https://gdr.openei.org/files/1254/ThermistorPerformance.docx",
"mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
"description": "Detailed information about thermistors installed week of 12/17/19"
},
{
"@type": "dcat:Distribution",
"title": "File List.txt",
"format": "txt",
"accessURL": "https://gdr.openei.org/files/1254/file_list.txt",
"mediaType": "text/plain",
"description": "List of files included in this submission."
},
{
"@type": "dcat:Distribution",
"title": "EGS Collab Circulation Testing Processed Data",
"format": "HTML",
"accessURL": "https://gdr.openei.org/submissions/1301",
"mediaType": "text/html",
"description": "Processed, cleaned, and reduced data. The current submission contain the raw data and the documentation needed to interpret and process the raw data. The channels to the interest of most potential users, including pressure, flow rate, and temperature, have been processed and shared in submission 1301."
},
{
"@type": "dcat:Distribution",
"title": "Wiki page for EGS Collab Experiment 1 Long Term Circulation Test",
"format": "HTML",
"accessURL": "https://openei.org/wiki/EGS_Collab_Experiment_1_Long_Term_Circulation_Test",
"mediaType": "text/html",
"description": "Wiki page for the test and data processing for the EGS Collab Experiment 1."
},
{
"@type": "dcat:Distribution",
"title": "EGS Collab Shift Reports",
"format": "HTML",
"accessURL": "https://openei.org/wiki/EGS_Collab_Shift_Reports",
"mediaType": "text/html",
"description": "A more complete description of major events during the long-term circulation experiment."
}
]
|
| DOI | 10.15121/1814005 |
| identifier | https://data.openei.org/submissions/7375 |
| issued | 2019-04-01T06:00:00Z |
| keyword |
[
"EGS",
"EGS Collab",
"Lead",
"SURF",
"Sanford Underground Research Facility",
"South Dakota",
"energy",
"experiment",
"field testing",
"flow",
"flow testing",
"fracturing",
"geothermal",
"hydraulic",
"injection",
"production",
"raw data",
"stim and flow system",
"stimulation",
"well"
]
|
| landingPage | https://gdr.openei.org/submissions/1254 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-10-25T17:29:44Z |
| programCode |
[
"019:006"
]
|
| projectLead | Lauren Boyd |
| projectNumber | EE0032708 |
| projectTitle | EGS Collab |
| publisher |
{
"name": "Lawrence Berkeley National Laboratory",
"@type": "org:Organization"
}
|
| spatial |
"{"type":"Polygon","coordinates":[[[-103.7577,44.3488],[-103.7465,44.3488],[-103.7465,44.3544],[-103.7577,44.3544],[-103.7577,44.3488]]]}"
|
| title | EGS Collab Experiment 1: Circulation Testing |