Evaluating Uncertainty of Nonlinear Microwave Calibration Models from Regression Residuals
The data used to generate the graphs in figures 2, 4, 5 and 6 of the paper "Evaluating Uncertainty of Nonlinear Microwave Calibrations from Regression Residuals". The full reference is D. F. Williams, B. Jamroz and J. D. Rezac, "Evaluating Uncertainty of Nonlinear Microwave Calibration Models With Regression Residuals," in IEEE Transactions on Microwave Theory and Techniques, vol. 68, no. 9, pp. 3776-3782, Sept. 2020, doi: 10.1109/TMTT.2020.3005170. 0. The file with data for Fig. X is named FigX.zip. 1. The file Fig X guide.txt in the top directory of each zip file describes which EasyPlot file was used to create the graph(s) in the figure. 2. The EasyPlot files were made with EasyPlot V 4.0.4, and document the data locations, legends, etc. EasyPlot column-selection format is as follows: "xyiiyy" or "xy..yy" means that column 1 was used for x axis, column 2 for first curve y values, column 5 for second curve y values, column 6 for third curve y values
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| accrualPeriodicity | irregular |
| bureauCode |
[
"006:55"
]
|
| contactPoint |
{
"fn": "Dylan Williams",
"hasEmail": "mailto:dylan.williams@nist.gov"
}
|
| description | The data used to generate the graphs in figures 2, 4, 5 and 6 of the paper "Evaluating Uncertainty of Nonlinear Microwave Calibrations from Regression Residuals". The full reference is D. F. Williams, B. Jamroz and J. D. Rezac, "Evaluating Uncertainty of Nonlinear Microwave Calibration Models With Regression Residuals," in IEEE Transactions on Microwave Theory and Techniques, vol. 68, no. 9, pp. 3776-3782, Sept. 2020, doi: 10.1109/TMTT.2020.3005170. 0. The file with data for Fig. X is named FigX.zip. 1. The file Fig X guide.txt in the top directory of each zip file describes which EasyPlot file was used to create the graph(s) in the figure. 2. The EasyPlot files were made with EasyPlot V 4.0.4, and document the data locations, legends, etc. EasyPlot column-selection format is as follows: "xyiiyy" or "xy..yy" means that column 1 was used for x axis, column 2 for first curve y values, column 5 for second curve y values, column 6 for third curve y values |
| distribution |
[
{
"title": "Gateway for Registered Data Access",
"accessURL": "https://nist.force.com/pdr?@id=ark:/88434/mds2-2172",
"description": "This page provides a registration form that must be completed before downloading the data."
},
{
"title": "Figure 2",
"mediaType": "application/x-zip-compressed",
"description": "Data for Figure 2",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig2.zip"
},
{
"title": "Figure 4",
"mediaType": "application/x-zip-compressed",
"description": "Data for Figure 4",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig4.zip"
},
{
"title": "Figure 5",
"mediaType": "application/x-zip-compressed",
"description": "Data for Figure 5",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig5.zip"
},
{
"title": "Figure 6",
"mediaType": "application/x-zip-compressed",
"description": "Data for Figure 6",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig6.zip"
},
{
"title": "Fig. 5",
"mediaType": "application/x-zip-compressed",
"description": "Data used to generate Figure 5",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig5.zip"
},
{
"title": "SHA256 File for Figure 2",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig2.zip.sha256"
},
{
"title": "SHA256 File for Figure 4",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig4.zip.sha256"
},
{
"title": "SHA256 File for Figure 5",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig5.zip.sha256"
},
{
"title": "SHA256 File for Figure 6",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2172/Fig6.zip.sha256"
}
]
|
| identifier | ark:/88434/mds2-2172 |
| issued | 2022-03-16 |
| keyword |
[
"Confidence intervals",
"coupling corrections",
"on-wafer measurement",
"prediction intervals."
]
|
| landingPage | https://data.nist.gov/od/id/mds2-2172 |
| language |
[
"en"
]
|
| license | https://www.nist.gov/open/license |
| modified | 2020-01-23 00:00:00 |
| programCode |
[
"006:045"
]
|
| publisher |
{
"name": "National Institute of Standards and Technology",
"@type": "org:Organization"
}
|
| references |
[
"https://doi.org/10.1109/TMTT.2020.3005170"
]
|
| rights | Purchase is not required for data downloading. Users must complete registration form to download data. |
| theme |
[
"Advanced Communications:Wireless (RF)",
"Mathematics and Statistics:Uncertainty quantification"
]
|
| title | Evaluating Uncertainty of Nonlinear Microwave Calibration Models from Regression Residuals |