Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate
Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards.
Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design.
PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8
BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "Paul Norton",
"@type": "vcard:Contact",
"hasEmail": "mailto:paul.norton@nrel.gov"
}
|
| dataQuality |
true
|
| description | Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2 |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate",
"format": "pdf",
"accessURL": "http://www.eere.energy.gov/buildings/publications/pdfs/building_america/houses_supplemental_dehumidification.pdf",
"mediaType": "application/pdf",
"description": "This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels.In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant."
},
{
"@type": "dcat:Distribution",
"title": "BDC Little Easy 2.1.0.0.BEopt",
"format": "BEopt",
"mediaType": "application/octet-stream",
"description": "BEopt File for home performance characteristics",
"downloadURL": "https://data.openei.org/files/5493/BDC%20Little%20Easy%202.1.0.0.BEopt"
},
{
"@type": "dcat:Distribution",
"title": "PHA Alexander BEopt 2.1.0.0.BEopt",
"format": "BEopt",
"mediaType": "application/octet-stream",
"description": "BEopt File for home performance characteristics",
"downloadURL": "https://data.openei.org/files/5493/PHA%20Alexander%20BEopt%202.1.0.0.BEopt"
},
{
"@type": "dcat:Distribution",
"title": "PHA Alexander BEopt 2.1.0.2.BEopt",
"format": "BEopt",
"mediaType": "application/octet-stream",
"description": "BEopt File for home performance characteristics
",
"downloadURL": "https://data.openei.org/files/5493/PHA%20Alexander%20BEopt%202.1.0.2.BEopt"
},
{
"@type": "dcat:Distribution",
"title": "DASplan and Data_NewOrleans PHA_v14.xlsb",
"format": "xlsb",
"mediaType": "application/vnd.ms-excel.sheet.binary.macroEnabled.12",
"description": "Project Home Again Data Spreadsheet",
"downloadURL": "https://data.openei.org/files/5493/DASplan%20and%20Data_NewOrleans%20PHA_v14.xlsb"
},
{
"@type": "dcat:Distribution",
"title": "2012-11-16 PHA 1- 8 RH Freq Plot.xlsx",
"format": "xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "Relative Humidity Data",
"downloadURL": "https://data.openei.org/files/5493/2012-11-16%20PHA%201-%208%20RH%20Freq%20Plot.xlsx"
},
{
"@type": "dcat:Distribution",
"title": "LA PHA Utility Bill Analysis.xlsx",
"format": "xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "Utility Bill Analysis for Project Home Again",
"downloadURL": "https://data.openei.org/files/5493/LA%20PHA%20Utility%20Bill%20Analysis.xlsx"
}
]
|
| DOI | 10.25984/2204229 |
| identifier | https://data.openei.org/submissions/5493 |
| issued | 2016-04-27T06:00:00Z |
| keyword |
[
"BuildingAmerica",
"building america",
"hot humid",
"humidity",
"indoor air quality",
"interior conditions",
"low energy high performance",
"new construction",
"occupant behavior",
"residential",
"single family",
"temperature",
"whole house dehumidifier"
]
|
| landingPage | https://data.openei.org/submissions/5493 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-11-01T16:40:31Z |
| programCode |
[
"019:002"
]
|
| projectNumber | FY12 AOP 1.9.1.19 |
| projectTitle | Building America |
| publisher |
{
"name": "National Renewable Energy Laboratory",
"@type": "org:Organization"
}
|
| spatial |
"{"type":"Polygon","coordinates":[[[-90.0715,29.9511],[-90.0715,29.9511],[-90.0715,29.9511],[-90.0715,29.9511],[-90.0715,29.9511]]]}"
|
| title | Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate |