Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data
In these data sets, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented. An indication of the sample is in the file name and in the first line of data.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "Tim Kneafsey",
"@type": "vcard:Contact",
"hasEmail": "mailto:tjkneafsey@lbl.gov"
}
|
| dataQuality |
true
|
| description | In these data sets, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented. An indication of the sample is in the file name and in the first line of data. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Stripa Granite.xlsx",
"format": "xlsx",
"accessURL": "https://gdr.openei.org/files/854/Test1StripaGraniteDataOnly.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "In these data sets of the Stripa Granite, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented."
},
{
"@type": "dcat:Distribution",
"title": "Brady BCH-03 4873ft Depth.xlsx",
"format": "xlsx",
"accessURL": "https://gdr.openei.org/files/854/Test2MetaSedimentaryBCH03_4873DataOnly.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "In this dataset of the Brady BCH-03 sample taken at 4873 feet, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented."
},
{
"@type": "dcat:Distribution",
"title": "Brady BCH-03 3589ft Depth.xlsx",
"format": "xlsx",
"accessURL": "https://gdr.openei.org/files/854/Test3BCH03_3589DataOnly.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "In this dataset of the Brady BCH-03 sample at 3589 feet deep, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented. An indication of the sample is in the file name and in the first line of data."
},
{
"@type": "dcat:Distribution",
"title": "Desert Peak 2476ft Depth.xlsx",
"format": "xlsx",
"accessURL": "https://gdr.openei.org/files/854/Test4DP2476DataOnly.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "For the Desert Peak sample taken at 2476 feet deep, this data set lists the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), and corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer. "
},
{
"@type": "dcat:Distribution",
"title": "Pickled Titanium Blank.xlsx",
"format": "xlsx",
"accessURL": "https://gdr.openei.org/files/854/Test5TiBlankDataOnly.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "In these data sets of the pickled titanium blank, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented."
}
]
|
| DOI | 10.15121/1422727 |
| identifier | https://data.openei.org/submissions/7047 |
| issued | 2016-09-30T06:00:00Z |
| keyword |
[
"Desert Peak",
"Pressure",
"Temperature",
"Titanium",
"aperture",
"differential pressure",
"experimental",
"fracture",
"fracture investigation",
"geochemistry",
"geothermal",
"granite",
"mechanics",
"pressure gradient"
]
|
| landingPage | https://gdr.openei.org/submissions/854 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2018-02-27T16:55:45Z |
| programCode |
[
"019:006"
]
|
| projectLead | Lauren Boyd |
| projectNumber | FY13 AOP 5.1 |
| projectTitle | Sustainability of Shear-Induced Permeability for EGS Reservoirs |
| publisher |
{
"name": "Lawrence Berkeley National Laboratory",
"@type": "org:Organization"
}
|
| spatial |
"{"type":"Polygon","coordinates":[[[-122.21672058105,37.888077102603],[-122.21672058105,37.888077102603],[-122.21672058105,37.888077102603],[-122.21672058105,37.888077102603],[-122.21672058105,37.888077102603]]]}"
|
| title | Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data |