Grid Connected Functionality

Published by National Renewable Energy Laboratory | Department of Energy | Metadata Last Checked: January 27, 2026 | Last Modified: 2024-12-18T17:36:27Z
Dataset demonstrating the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the-loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations.

Resources

1 resource available

  • This database was populated from the demo-run of VOLTTRON in ESIF, using the historian agent. https://github.com/VOLTTRON/volttron/wiki/SQL-Historian Format: List of topics and their units. Attribute Unit datalogger/log/dac/EV_AC Watts datalogger/log/dac/evse Watts datalogger/log/dac/house Watts datalogger/log/dac/hpwh Watts datalogger/log/dac/hvac Watts datalogger/log/dac/light Watts datalogger/log/dac/poolpump Watts datalogger/log/evse_relay_set/max_charge_rate_set Watts datalogger/log/evse_relay_set/mode_set_CEA2045 string datalogger/log/evse_relay_state/max_charge_rate Watts datalogger/log/evse_relay_state/mode_CEA2045 String datalogger/log/frequency_regulation/frequency_regulation float datalogger/log/hpwh_relay_set/control_signals_API String datalogger/log/hpwh_relay_state_mode/hpwh_mode_API String datalogger/log/hpwh_relay_state/hpwh_temp_bottom F datalogger/log/hpwh_relay_state/hpwh_temp_top F datalogger/log/hvac_relay_setpoint_set/setpoint F datalogger/log/hvac_relay_state/air_temp F datalogger/log/hvac_relay_state/hvac_mode integer datalogger/log/hvac_relay_state/setpoint F datalogger/log/light_relay_mode_set/light_selector_set integer datalogger/log/light_relay_setpoint_set/light_intensity_set integer datalogger/log/light_relay_state/IntensityA integer datalogger/log/light_relay_state/IntensityB integer datalogger/log/light_relay_state/light_selector_mode integer datalogger/log/poolpump_relay_set/max_charge_rate_set Watts datalogger/log/poolpump_relay_set/mode_set integer datalogger/log/poolpump_relay_state/max_power Watts datalogger/log/poolpump_relay_state/mode_CEA2045 string datalogger/log/sc_house/provided_EV Watts datalogger/log/sc_house/provided_house Watts datalogger/log/sc_house/provided_HVAC Watts datalogger/log/sc_house/requested Watts datalogger/log/simulation/total_reg_provided Watts datalogger/log/simulation/total_reg_requested Watts All timestamps are strings of the form "%Y-%m-%d %H:%M:%S" All topics containing 'zz_simulation' are the power consumption of the simulated appliances in Watts. The Topics table contains a list of availabe topics on the volttron message bus. (topic_id INTEGER PRIMARY KEY, topic_name TEXT NOT NULL, UNIQUE(topic_name)) The data table is a timeseries database of the topics from the topics table mapped by topic_id. (ts timestamp NOT NULL, topic_id INTEGER NOT NULL, value_string TEXT NOT NULL, UNIQUE(ts, topic_id))

    (TS TIMESTAMP NOT NULL, TOPIC_ID INTEGER NOT NULL, VALUE_STRING TEXT NOT NULL, UNIQUE(TS, TOPIC_ID))