Influence of machine anvil wear on Charpy test results
We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances).
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| accrualPeriodicity | irregular |
| bureauCode |
[
"006:55"
]
|
| contactPoint |
{
"fn": "Enrico Lucon",
"hasEmail": "mailto:enrico.lucon@nist.gov"
}
|
| description | We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances). |
| distribution |
[
{
"title": "DOI Access for Influence of machine anvil wear on Charpy test results",
"accessURL": "https://doi.org/10.18434/M32224"
},
{
"title": "Data for high-energy specimens",
"format": "CSV file",
"mediaType": "text/csv",
"description": "Test results for high-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2224/Influence%20anvil%20wear%20-%20High%20energy.csv"
},
{
"title": "Data for low-energy specimens",
"format": "CSV file",
"mediaType": "text/csv",
"description": "Test results for low-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2224/Influence%20anvil%20wear%20-%20Low%20energy.csv"
},
{
"title": "Test results for super-high-energy specimens",
"format": "CSV file",
"mediaType": "text/csv",
"description": "Test results for super-high-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2224/Influence%20anvil%20wear%20-%20Super-High%20energy.csv"
},
{
"title": "SHA256 File for Data for high-energy specimens",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2224/Influence%20anvil%20wear%20-%20High%20energy.csv.sha256"
},
{
"title": "SHA256 File for Data for low-energy specimens",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2224/Influence%20anvil%20wear%20-%20Low%20energy.csv.sha256"
},
{
"title": "SHA256 File for Test results for super-high-energy specimens",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2224/Influence%20anvil%20wear%20-%20Super-High%20energy.csv.sha256"
}
]
|
| identifier | ark:/88434/mds2-2224 |
| issued | 2020-04-28 |
| keyword |
[
"ASTM E23",
"Absorbed energy",
"Charpy",
"ISO 148",
"machine anvils",
"span",
"wear"
]
|
| landingPage | https://data.nist.gov/od/id/mds2-2224 |
| language |
[
"en"
]
|
| license | https://www.nist.gov/open/license |
| modified | 2020-01-24 00:00:00 |
| programCode |
[
"006:045"
]
|
| publisher |
{
"name": "National Institute of Standards and Technology",
"@type": "org:Organization"
}
|
| references |
[
"https://doi.org/10.6028/NIST.TN.2089",
"https://nvlpubs.nist.gov/nistpubs/jres/125/jres.125.015.pdf"
]
|
| theme |
[
"Infrastructure",
"Materials:Materials characterization",
"Materials:Metals"
]
|
| title | Influence of machine anvil wear on Charpy test results |