Josephson arbitrary waveform synthesizer for ac voltage calibration, CPEM 2022
This is the dataset for 4 publishable figures in 2 page abstracted titled "Josephson arbitrary waveform synthesizer for ac voltage calibrations" submitted to the Conference on Precision Electromagnetic Measurements, CPEM 2022. QLR=Quantum Locking Range.Fig. 1. QLR (2 V rms waveforms) as a function of the dc bias current offset in all 4 arrays of Bias 1.Fig. 2. QLR (2 V rms waveforms) as a function of the compensation current amplitude in all 4 arrays of Bias 1.Fig. 3. QLR (2 V rms waveform) as a function of the pulse amplitude on Bias 1 or Bias 2 high-speed current pulse channel.Fig. 4. QLR (2 V rms waveforms) as a function of the compensation current phase in all 4 arrays of Bias 1.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"006:55"
]
|
| contactPoint |
{
"fn": "Alain Rufenacht",
"hasEmail": "mailto:alain.rufenacht@nist.gov"
}
|
| description | This is the dataset for 4 publishable figures in 2 page abstracted titled "Josephson arbitrary waveform synthesizer for ac voltage calibrations" submitted to the Conference on Precision Electromagnetic Measurements, CPEM 2022. QLR=Quantum Locking Range.Fig. 1. QLR (2 V rms waveforms) as a function of the dc bias current offset in all 4 arrays of Bias 1.Fig. 2. QLR (2 V rms waveforms) as a function of the compensation current amplitude in all 4 arrays of Bias 1.Fig. 3. QLR (2 V rms waveform) as a function of the pulse amplitude on Bias 1 or Bias 2 high-speed current pulse channel.Fig. 4. QLR (2 V rms waveforms) as a function of the compensation current phase in all 4 arrays of Bias 1. |
| distribution |
[
{
"title": "Figure 1",
"format": "CSV",
"mediaType": "text/csv",
"description": "Fig. 1. QLR (2 V rms waveforms) as a function of the dc bias current offset in all 4 arrays of Bias 1.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig1%20Bias%20Current%20DC%20Offset.csv"
},
{
"title": "Figure 2",
"format": "CSV",
"mediaType": "text/csv",
"description": "Fig. 2. QLR (2 V rms waveforms) as a function of the compensation current amplitude in all 4 arrays of Bias 1.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig2%20Compensation%20Amplitude%20Dither.csv"
},
{
"title": "Figure 3",
"format": "CSV",
"mediaType": "text/csv",
"description": "Fig. 3. QLR (2 V rms waveform) as a function of the pulse amplitude on Bias 1 or Bias 2 high-speed current pulse channel.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig3%20Pulse%20Amplitude%20Dither.csv"
},
{
"title": "Figure 4",
"format": "CSV",
"mediaType": "text/csv",
"description": "Fig. 4. QLR (2 V rms waveforms) as a function of the compensation current phase in all 4 arrays of Bias 1.",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2682/Fig4%20Compensation%20Phase%20Dither.csv"
},
{
"title": "Readme",
"mediaType": "text/plain",
"downloadURL": "https://data.nist.gov/od/ds/mds2-2682/2682_README.txt"
}
]
|
| identifier | ark:/88434/mds2-2682 |
| issued | 2022-07-20 |
| keyword |
[
"Josephson arrays",
"digital-analog conversion",
"quantization",
"signal synthesis",
"standards",
"superconducting integrated circuits",
"voltage measurement"
]
|
| language |
[
"en"
]
|
| license | https://www.nist.gov/open/license |
| modified | 2022-06-14 00:00:00 |
| programCode |
[
"006:045"
]
|
| publisher |
{
"name": "National Institute of Standards and Technology",
"@type": "org:Organization"
}
|
| theme |
[
"Metrology:Electrical/electromagnetic metrology",
"Standards:Reference instruments"
]
|
| title | Josephson arbitrary waveform synthesizer for ac voltage calibration, CPEM 2022 |