LandRAY PTO Testing Utilizing the NREL NWTC 5MW Dynamometer
The overarching project objective is to demonstrate the feasibility of using an innovative PowerTake-Off (PTO) Module in Columbia Power's utility-scale wave energy converter (WEC). The PTO Module uniquely combines a large-diameter, direct-drive, rotary permanent magnet generator; a patent-pending rail-bearing system; and a corrosion-resistant fiber-reinforced-plastic structure
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "Ken Rhinefrank",
"@type": "vcard:Contact",
"hasEmail": "mailto:krhinefrank@columbiapwr.com"
}
|
| dataQuality |
true
|
| description | The overarching project objective is to demonstrate the feasibility of using an innovative PowerTake-Off (PTO) Module in Columbia Power's utility-scale wave energy converter (WEC). The PTO Module uniquely combines a large-diameter, direct-drive, rotary permanent magnet generator; a patent-pending rail-bearing system; and a corrosion-resistant fiber-reinforced-plastic structure |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Cost Breakdown Structure.xlsx",
"format": "xlsx",
"accessURL": "https://mhkdr.openei.org/files/120/DE-EE0006399%20M13.1.1%20Cost%20Breakdown%20Structure%20PD%20v1.0%2001-17-2016.xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "This document summarizes the Cost Breakdown Structure of the Columbia Power Technologies StingRAY wave energy converter (WEC) design."
},
{
"@type": "dcat:Distribution",
"title": "Pre-Project TAEP Calculations.pdf",
"format": "pdf",
"accessURL": "https://mhkdr.openei.org/files/120/DE-EE0006399%20M13.1.1%20DDS1-i%20TAEP%20Calculations%20PD%20v1.0%2011-17-2015.pdf",
"mediaType": "application/pdf",
"description": "This document summarizes the pre-Project assessment of the Theoretical Annual Energy Production (TAEP) for the Columbia Power Technologies StingRAY wave energy converter (WEC) design."
},
{
"@type": "dcat:Distribution",
"title": "Intermediate Project TAEP calculations.pdf",
"format": "pdf",
"accessURL": "https://mhkdr.openei.org/files/120/DE-EE0006399%20M13.1.1%20DDS1-p%20TAEP%20Calculations%20PD%20v1.1%2011-16-2015.pdf",
"mediaType": "application/pdf",
"description": "This document summarizes the intermediate assessment of the Theoretical Annual Energy Production (TAEP) for the Columbia Power Technologies StingRAY wave energy converter (WEC) design."
}
]
|
| DOI | 10.15473/1421985 |
| identifier | https://data.openei.org/submissions/7822 |
| issued | 2016-06-13T06:00:00Z |
| keyword |
[
"AEP",
"CBS",
"Columbia Power",
"Columbia Power Technologies",
"Direct-Drive",
"Dynamometer",
"Grid-Connected",
"Hawaii",
"Hydrokinetic",
"Ireland",
"LCOE",
"LandRAY",
"MHK",
"Marine",
"Offshore",
"Oregon",
"PTO",
"Performance",
"Power-Take-Off",
"Reliability",
"Renewable Energy",
"SPA",
"SeaRAY",
"Wave Energy Converter",
"absorber",
"annual",
"attenuator",
"breakdown",
"budget",
"converter",
"cost",
"cost assessment",
"cost breakdown structure",
"cost summary",
"economics",
"energy",
"field",
"float",
"heave",
"hybrid",
"large-diameter",
"levelized cost of energy",
"magnet",
"mean annual power",
"permanent",
"point",
"power",
"production",
"surface attenuator",
"taep",
"technology",
"test",
"theoretical",
"theoretical annual energy production",
"wave",
"wec"
]
|
| landingPage | https://mhkdr.openei.org/submissions/120 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2020-07-29T18:01:51Z |
| programCode |
[
"019:009"
]
|
| projectLead | Gary Nowakowski |
| projectNumber | EE0006399 |
| projectTitle | Build and Test of a Novel, Commercial-Scale Wave Energy Direct-Drive Rotary Power Take-Off Under Realistic Open-Ocean Conditions |
| publisher |
{
"name": "Columbia Power Technologies, Inc.",
"@type": "org:Organization"
}
|
| spatial |
"{"type":"Polygon","coordinates":[[[-105.21547222222,-83],[-105.21547222222,-83],[-105.21547222222,39.913972222222],[-105.21547222222,39.913972222222],[-105.21547222222,-83]]]}"
|
| title | LandRAY PTO Testing Utilizing the NREL NWTC 5MW Dynamometer |