Return to search results
Passive water-quality sampling at discrete vertical intervals to support the development of a conceptual site model at the Geneva Industries/Fuhrmann Energy Superfund Site, Houston, Texas, 2023
The Geneva Industries/Fuhrmann Energy Superfund Site (hereinafter referred to as "the Site") in southeastern Houston, Texas was historically used as a site for petroleum exploration and petrochemical production and is currently (2024) inactive. Previous remedies to clean up the contaminated site included the excavation and off-site disposal of polychlorinated biphenyl (PCB)-contaminated soils, capping the Site and surrounding it with a perimeter slurry wall to contain remaining constituents in the soil and groundwater, the recovery and treatment of trichloroethylene (TCE)-contaminated groundwater, and institutional controls (U.S. Environmental Protection Agency [EPA], 2018). A conceptual site model (CSM) does not yet exist and is needed to (1) understand how site conditions have changed since earlier investigations; (2) re-evaluate contaminants of concerns at the Site; and (3) determine whether additional remedial actions are needed. A five-phase approach was proposed by the U.S. Geological Survey (USGS) to obtain the data needed to develop a CSM. As the third phase in that approach, the USGS in cooperation with the EPA, collected groundwater samples at discrete vertical sampling intervals from four wells, former recovery well RW-1R and monitoring wells MW-24, MW-101, and MW-102, using three types of passive samplers at the Site in September 2023.
Complete Metadata
| accessLevel | public |
|---|---|
| bureauCode |
[
"010:12"
]
|
| contactPoint |
{
"fn": "Oklahoma-Texas Water Science Center Public Information Officer",
"@type": "vcard:Contact",
"hasEmail": "mailto:gs-w-txpublic-info@usgs.gov"
}
|
| description | The Geneva Industries/Fuhrmann Energy Superfund Site (hereinafter referred to as "the Site") in southeastern Houston, Texas was historically used as a site for petroleum exploration and petrochemical production and is currently (2024) inactive. Previous remedies to clean up the contaminated site included the excavation and off-site disposal of polychlorinated biphenyl (PCB)-contaminated soils, capping the Site and surrounding it with a perimeter slurry wall to contain remaining constituents in the soil and groundwater, the recovery and treatment of trichloroethylene (TCE)-contaminated groundwater, and institutional controls (U.S. Environmental Protection Agency [EPA], 2018). A conceptual site model (CSM) does not yet exist and is needed to (1) understand how site conditions have changed since earlier investigations; (2) re-evaluate contaminants of concerns at the Site; and (3) determine whether additional remedial actions are needed. A five-phase approach was proposed by the U.S. Geological Survey (USGS) to obtain the data needed to develop a CSM. As the third phase in that approach, the USGS in cooperation with the EPA, collected groundwater samples at discrete vertical sampling intervals from four wells, former recovery well RW-1R and monitoring wells MW-24, MW-101, and MW-102, using three types of passive samplers at the Site in September 2023. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Digital Data",
"format": "XML",
"accessURL": "https://doi.org/10.5066/P9GGYO21",
"mediaType": "application/http",
"description": "Landing page for access to the data"
},
{
"@type": "dcat:Distribution",
"title": "Original Metadata",
"format": "XML",
"mediaType": "text/xml",
"description": "The metadata original format",
"downloadURL": "https://data.usgs.gov/datacatalog/metadata/USGS.65394acad34ee4b6e05bbbe8.xml"
}
]
|
| identifier | http://datainventory.doi.gov/id/dataset/USGS_65394acad34ee4b6e05bbbe8 |
| keyword |
[
"AGI Gore sampler",
"Environmental Protection Agency",
"Geneva Industries/Fuhrmann Energy Superfund Site",
"Harris County",
"Houston",
"Superfund",
"Texas",
"USGS:65394acad34ee4b6e05bbbe8",
"conceptual site model",
"diffusion",
"geoscientificInformation",
"groundwater",
"hydrology",
"low-density polyethylene strip",
"passive diffusion bag",
"passive sampling",
"polychlorinated biphenyls",
"semivolatile organic compounds",
"volatile organic compounds"
]
|
| modified | 2024-09-13T00:00:00Z |
| publisher |
{
"name": "U.S. Geological Survey",
"@type": "org:Organization"
}
|
| spatial | -95.2502000, 29.6593200, -95.2494900, 29.6598900 |
| theme |
[
"Geospatial"
]
|
| title | Passive water-quality sampling at discrete vertical intervals to support the development of a conceptual site model at the Geneva Industries/Fuhrmann Energy Superfund Site, Houston, Texas, 2023 |