Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits
The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit-shallow and deep-with savings levels that approach the Building America program goal of reducing whole-house energy use by 40%.
Home 7 - Merritt Island, FL 32952
Home 39 - Palm Bay, FL 32907 - BEOpt 2.1.0.2
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "David Beal",
"@type": "vcard:Contact",
"hasEmail": "mailto:david@fsec.ucf.edu"
}
|
| dataQuality |
true
|
| description | The U.S. Department of Energy's Building America research team Building America Partnership for Improved Residential Construction is collaborating with Florida Power & Light (FPL) to conduct a phased residential energy-efficiency retrofit program. This research seeks to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit-shallow and deep-with savings levels that approach the Building America program goal of reducing whole-house energy use by 40%. Home 7 - Merritt Island, FL 32952 Home 39 - Palm Bay, FL 32907 - BEOpt 2.1.0.2 |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Phased Deep Retrofit Field Monitoring Data",
"format": "HTML",
"accessURL": "http://www.infomonitors.com/pdr/",
"mediaType": "text/html",
"description": "Detailed, real-time sub-metered data of 62 homes in Florida pre- and post-retrofit."
},
{
"@type": "dcat:Distribution",
"title": "Phased Retrofits in Existing Homes in Florida Phase I - Shallow and Deep Retrofits",
"format": "pdf",
"accessURL": "https://www.nrel.gov/docs/fy16osti/65327.pdf",
"mediaType": "application/pdf",
"description": "DOE Report"
},
{
"@type": "dcat:Distribution",
"title": "pdr7 Existing w_ Min Replace.xml",
"format": "xml",
"mediaType": "text/xml",
"description": "BEopt version 2.1.0.2",
"downloadURL": "https://data.openei.org/files/5220/pdr7-existing-w-min-replace.xml"
},
{
"@type": "dcat:Distribution",
"title": "pdr7 deep.xml",
"format": "xml",
"mediaType": "text/xml",
"description": "Deep retrofit of PDR House 7, BEopt 2.1.0.2",
"downloadURL": "https://data.openei.org/files/5220/pdr7-deep.xml"
},
{
"@type": "dcat:Distribution",
"title": "PDR Specs and Measures 7-26-16.xlsx",
"format": "xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "Home Data summary and measurements",
"downloadURL": "https://data.openei.org/files/5220/PDR%20Specs%20and%20Measures%207-26-16%20%281%29.xlsx"
},
{
"@type": "dcat:Distribution",
"title": "PDR House characteristics.xlsx",
"format": "xlsx",
"mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"description": "Housing Information for the PDR repository ",
"downloadURL": "https://data.openei.org/files/5220/PDR%20House%20characteristics.xlsx"
},
{
"@type": "dcat:Distribution",
"title": "pdr39 Existing w_ Min Replace.xml",
"format": "xml",
"mediaType": "text/xml",
"description": "Phased Deep Retrofit Home 39 as found, BEopt 2.1.0.2",
"downloadURL": "https://data.openei.org/files/5220/pdr39-existing-w-min-replace.xml"
},
{
"@type": "dcat:Distribution",
"title": "pdr39 shallow.xml",
"format": "xml",
"mediaType": "text/xml",
"description": "Phased Deep Retrofit House 39 Shallow retrofit, BEopt 2.1.0.2",
"downloadURL": "https://data.openei.org/files/5220/pdr7-shallow_2.xml"
},
{
"@type": "dcat:Distribution",
"title": "pdr39 deep.xml",
"format": "xml",
"mediaType": "text/xml",
"description": "Phased Deep Retrofit House 39 deep retrofit, BEopt 2.1.0.2",
"downloadURL": "https://data.openei.org/files/5220/pdr39-deep.xml"
},
{
"@type": "dcat:Distribution",
"title": "pdr7 shallow.xml",
"format": "xml",
"mediaType": "text/xml",
"description": "Shallow retrofit of PDR house 7 BEopt 2.1.0.2",
"downloadURL": "https://data.openei.org/files/5220/pdr7-shallow.xml"
}
]
|
| DOI | 10.25984/2204241 |
| identifier | https://data.openei.org/submissions/5220 |
| issued | 2016-04-27T06:00:00Z |
| keyword |
[
"BuildingAmerica",
"building america",
"community",
"cost effectiveness",
"deep energy retrofit",
"domestic hot water systems",
"existing home",
"heat pump water heater",
"humidity",
"hvac",
"lighting",
"phased deep retrofit",
"pool pumps",
"residential",
"shallow retrofits"
]
|
| landingPage | https://data.openei.org/submissions/5220 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-11-01T16:41:53Z |
| programCode |
[
"019:002"
]
|
| projectNumber | FY15 AOP 1.9.1.19 |
| projectTitle | Building America |
| publisher |
{
"name": "University of Central Florida - Florida Solar Energy Center",
"@type": "org:Organization"
}
|
| spatial |
"{"type":"Polygon","coordinates":[[[-83.39573593750004,24.747040690924937],[-78.9683234375,24.747040690924937],[-78.9683234375,28.762145278772028],[-83.39573593750004,28.762145278772028],[-83.39573593750004,24.747040690924937]]]}"
|
| title | Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits |