Return to search results
Retrofitting a 1960s Split-Level Cold-Climate Home
The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Connecticut, to evaluate and implement a cost-effective solution package that met the requirements of 30% source energy savings compared to the pre-retrofit performance. This home had already been updated aesthetically (kitchen and bathrooms), so the owners wanted the energy-efficiency measures to be as non-disruptive to the interior finishes as possible.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"019:20"
]
|
| contactPoint |
{
"fn": "Sriknath Puttagunta",
"@type": "vcard:Contact",
"hasEmail": "mailto:sputtagunta@swinter.com"
}
|
| dataQuality |
true
|
| description | The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Connecticut, to evaluate and implement a cost-effective solution package that met the requirements of 30% source energy savings compared to the pre-retrofit performance. This home had already been updated aesthetically (kitchen and bathrooms), so the owners wanted the energy-efficiency measures to be as non-disruptive to the interior finishes as possible. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Retrofitting a 1960s Split-Level Cold-Climate Home",
"format": "pdf",
"accessURL": "https://www.nrel.gov/docs/fy15osti/64353.pdf",
"mediaType": "application/pdf",
"description": "DOE Report"
},
{
"@type": "dcat:Distribution",
"title": "37OakRetrofit.beopt",
"format": "beopt",
"mediaType": "application/octet-stream",
"description": "BEopt File for home performance characteristics",
"downloadURL": "https://data.openei.org/files/4670/37oakretrofit.beopt"
},
{
"@type": "dcat:Distribution",
"title": "BPC-Green-builders.beopt",
"format": "beopt",
"mediaType": "application/octet-stream",
"description": "BEopt File for home performance characteristics ",
"downloadURL": "https://data.openei.org/files/4670/bpc-green-builders.beopt"
}
]
|
| DOI | 10.25984/2204260 |
| identifier | https://data.openei.org/submissions/4670 |
| issued | 2016-04-27T06:00:00Z |
| keyword |
[
"BuildingAmerica",
"airtightness",
"building america",
"cellulose",
"closed-cell spray foam insulation",
"cold",
"cost effectiveness",
"existing home",
"natural gas condensing tankless boiling",
"occupied home",
"residential",
"retrofit",
"thermal resistance",
"unvented attic",
"utility bill validation"
]
|
| landingPage | https://data.openei.org/submissions/4670 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-11-01T16:43:41Z |
| programCode |
[
"019:000",
"019:002"
]
|
| projectNumber | FY15 AOP 1.9.1.19 |
| projectTitle | Building America |
| publisher |
{
"name": "Steven Winter Associates of the Consortium for Advanced Residential Buildings",
"@type": "org:Organization"
}
|
| spatial |
"{"type":"Polygon","coordinates":[[[-73.3579,41.1415],[-73.3579,41.1415],[-73.3579,41.1415],[-73.3579,41.1415],[-73.3579,41.1415]]]}"
|
| title | Retrofitting a 1960s Split-Level Cold-Climate Home |