Rhodamine WT dye concentration profiles measured at fixed stations in the Brandon Road Lock chamber near Rockdale, Illinois (October 20, 2015)
A Turner Designs C3 submersible fluorometer was deployed in the Brandon Road Lock chamber (BRLD) near Rockdale, Illinois, to measure Rhodamine WT dye concentrations during a U.S. Geological Survey dye study conducted on October 20, 2015. The lock chamber at BRLD was dyed with 4 liters of Rhodamine WT dye during a routine filling procedure. Measurements of dye concentration profiles were collected at 15 stations in the lock chamber and capture the three-dimensional distribution of the dye in the chamber after filling, after the lock was emptied, and after a 17-minute flushing operation of the lock. A series of five taglines and rope and pulley systems were used to position the fluorometer at each station to avoid putting a boat in the lock chamber and creating additional mixing. Fluorometer readings were taken at a frequency of 1 measurement every second.
Complete Metadata
| accessLevel | public |
|---|---|
| bureauCode |
[
"010:12"
]
|
| contactPoint |
{
"fn": "P. Ryan Jackson",
"@type": "vcard:Contact",
"hasEmail": "mailto:pjackson@usgs.gov"
}
|
| description | A Turner Designs C3 submersible fluorometer was deployed in the Brandon Road Lock chamber (BRLD) near Rockdale, Illinois, to measure Rhodamine WT dye concentrations during a U.S. Geological Survey dye study conducted on October 20, 2015. The lock chamber at BRLD was dyed with 4 liters of Rhodamine WT dye during a routine filling procedure. Measurements of dye concentration profiles were collected at 15 stations in the lock chamber and capture the three-dimensional distribution of the dye in the chamber after filling, after the lock was emptied, and after a 17-minute flushing operation of the lock. A series of five taglines and rope and pulley systems were used to position the fluorometer at each station to avoid putting a boat in the lock chamber and creating additional mixing. Fluorometer readings were taken at a frequency of 1 measurement every second. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Digital Data",
"format": "XML",
"accessURL": "http://dx.doi.org/10.5066/F77W69B7",
"mediaType": "application/http",
"description": "Landing page for access to the data"
},
{
"@type": "dcat:Distribution",
"title": "Original Metadata",
"format": "XML",
"mediaType": "text/xml",
"description": "The metadata original format",
"downloadURL": "https://data.usgs.gov/datacatalog/metadata/USGS.57976ac7e4b021cadec9789d.xml"
}
]
|
| identifier | http://datainventory.doi.gov/id/dataset/USGS_57976ac7e4b021cadec9789d |
| keyword |
[
"Brandon Road Lock and Dam",
"Des Plaines River",
"Dye",
"Illinois",
"Lock exchange",
"Rockdale",
"Tracer",
"USGS:57976ac7e4b021cadec9789d",
"Will County"
]
|
| modified | 2020-08-14T00:00:00Z |
| publisher |
{
"name": "U.S. Geological Survey",
"@type": "org:Organization"
}
|
| spatial | -88.103919, 41.502729, -88.10209, 41.503969 |
| theme |
[
"Geospatial"
]
|
| title | Rhodamine WT dye concentration profiles measured at fixed stations in the Brandon Road Lock chamber near Rockdale, Illinois (October 20, 2015) |