S&T Project 19078 Final Report: Rotor Installed Corona Mapping of Stator Windings within Large Diameter Hydro Generators

Published by Bureau of Reclamation | Department of the Interior | Metadata Last Checked: January 06, 2026 | Last Modified: 2021-09-21T19:49:46Z
This research utilized near field communication antennas to map partial discharge activity, with slot level resolution, throughout a stator winding of a service aged hydro generator with minimal disassembly of the asset and without the need to remove the rotor. Results suggest that, with further research and development, this method may be a viable replacement for conventional corona probe testing. As a replacement, this method would allow for trending of partial discharge activity in each slot of large stator windings while significantly reducing costs, hazards, and risks associated with obtaining this data, which would be a substantial leap in diagnostic capabilities within the industry.

data.gov

An official website of the GSA's Technology Transformation Services

Looking for U.S. government information and services?
Visit USA.gov