T Wave Alternans in high arrhythmic risk patients: Analysis in time and frequency domains: A pilot study
Background
T wave alternans (TA) is a repolarisation phenomenon manifesting as a microvolt beat to beat change in the amplitude of the T wave and ST segment. TA has been shown to be a predictor of arrhythmic risk in unselected myocardial infarction populations. TA has not been used to differentiate risk within the ischaemic cardiomyopathy population.
Methods
The subjects investigated comprised, Group 1: 7 stable patients with remote (>20 months) extensive myocardial scarring and no arrhythmic events (NYHA 3 and 4). Group2: 9 post infarction patients with malignant arrhythmia and implantable defibrillator. During breath holding, 20 continuous QRST complexes from each patients X, Y and Z leads were digitally recorded. Time domain, resultant absolute difference vectors (ATA), were calculated for alternate resultant T wave sequences. Group differences between the magnitude and temporal distribution of mean ATAs and their spectral and cross-spectral analysis were compared.
Results
Group 1 v Group 2 mean ATAs were 10.7 (7.17) v 11.7 (8.48) respectively, not significant. Each group had a homogenous temporal distribution of ATAs. Both group's largest mean ATA frequency components were between 0 to 25 Hz, the largest ATA component being at the DC frequency. Cross spectral analysis showed no significant differences in group ATA frequency content.
Conclusion
The frequency content and microvolt magnitude of T wave alternans was not significantly different in these two groups. The specificity of T wave alternans for differentiating arrhythmic risk in post infarction scarring and heart failure needs investigation.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"009:25"
]
|
| contactPoint |
{
"fn": "NIH",
"@type": "vcard:Contact",
"hasEmail": "mailto:info@nih.gov"
}
|
| description | Background T wave alternans (TA) is a repolarisation phenomenon manifesting as a microvolt beat to beat change in the amplitude of the T wave and ST segment. TA has been shown to be a predictor of arrhythmic risk in unselected myocardial infarction populations. TA has not been used to differentiate risk within the ischaemic cardiomyopathy population. Methods The subjects investigated comprised, Group 1: 7 stable patients with remote (>20 months) extensive myocardial scarring and no arrhythmic events (NYHA 3 and 4). Group2: 9 post infarction patients with malignant arrhythmia and implantable defibrillator. During breath holding, 20 continuous QRST complexes from each patients X, Y and Z leads were digitally recorded. Time domain, resultant absolute difference vectors (ATA), were calculated for alternate resultant T wave sequences. Group differences between the magnitude and temporal distribution of mean ATAs and their spectral and cross-spectral analysis were compared. Results Group 1 v Group 2 mean ATAs were 10.7 (7.17) v 11.7 (8.48) respectively, not significant. Each group had a homogenous temporal distribution of ATAs. Both group's largest mean ATA frequency components were between 0 to 25 Hz, the largest ATA component being at the DC frequency. Cross spectral analysis showed no significant differences in group ATA frequency content. Conclusion The frequency content and microvolt magnitude of T wave alternans was not significantly different in these two groups. The specificity of T wave alternans for differentiating arrhythmic risk in post infarction scarring and heart failure needs investigation. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Official Government Data Source",
"mediaType": "text/html",
"description": "Visit the original government dataset for complete information, documentation, and data access.",
"downloadURL": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC101381/"
}
]
|
| identifier | https://healthdata.gov/api/views/p7zr-wt2z |
| issued | 2025-07-14 |
| keyword |
[
"arrhythmic-risk",
"electrophysiology",
"myocardial-infarction",
"nih",
"t-wave-alternans"
]
|
| landingPage | https://healthdata.gov/d/p7zr-wt2z |
| modified | 2025-09-06 |
| programCode |
[
"009:032"
]
|
| publisher |
{
"name": "National Institutes of Health",
"@type": "org:Organization"
}
|
| theme |
[
"NIH"
]
|
| title | T Wave Alternans in high arrhythmic risk patients: Analysis in time and frequency domains: A pilot study |