The measurement of lung water
Introduction:
In this review, we compare the spectrum of currently available methods for quantifying pulmonary edema in patients.
Review:
Imaging and indicator dilution techniques comprise the most common strategies for measuring lung water at the bedside. The most accurate (within 10% of the gravimetric gold standard) and most reproducible (< 5% between-test variation) are also, unfortunately, the most expensive and most difficult to implement for purposes of large-scale clinical trials or for routine clinical practice.
Conclusion:
The standard chest radiograph remains the best screening test for the detection of pulmonary edema. Indicator-dilution techniques are probably the best available method at present for quantitation in patient groups.
Complete Metadata
| @type | dcat:Dataset |
|---|---|
| accessLevel | public |
| bureauCode |
[
"009:25"
]
|
| contactPoint |
{
"fn": "NIH",
"@type": "vcard:Contact",
"hasEmail": "mailto:info@nih.gov"
}
|
| description | Introduction: In this review, we compare the spectrum of currently available methods for quantifying pulmonary edema in patients. Review: Imaging and indicator dilution techniques comprise the most common strategies for measuring lung water at the bedside. The most accurate (within 10% of the gravimetric gold standard) and most reproducible (< 5% between-test variation) are also, unfortunately, the most expensive and most difficult to implement for purposes of large-scale clinical trials or for routine clinical practice. Conclusion: The standard chest radiograph remains the best screening test for the detection of pulmonary edema. Indicator-dilution techniques are probably the best available method at present for quantitation in patient groups. |
| distribution |
[
{
"@type": "dcat:Distribution",
"title": "Official Government Data Source",
"mediaType": "text/html",
"description": "Visit the original government dataset for complete information, documentation, and data access.",
"downloadURL": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC137228/"
}
]
|
| identifier | https://healthdata.gov/api/views/nusx-fpru |
| issued | 2025-07-14 |
| keyword |
[
"imaging-techniques",
"indicator-dilution",
"lung-water",
"nih",
"pulmonary-edema"
]
|
| landingPage | https://healthdata.gov/d/nusx-fpru |
| modified | 2025-09-06 |
| programCode |
[
"009:032"
]
|
| publisher |
{
"name": "National Institutes of Health",
"@type": "org:Organization"
}
|
| theme |
[
"NIH"
]
|
| title | The measurement of lung water |