Found 9 datasets matching "vector network analyzer".
-
This repository contains all of the data published in the figures of the paper "On-Wafer Vector-Network-Analyzer Measurements at mK Temperatures." Manuscript DOI:...
- text
- text files in zip file
- text files in a zip file
- text files in a zip file
- text in a zip file
- text files in a zip file
- +12 more
Search relevance: 195.34 | Views last month: 0 -
data published in paper "On-Wafer Device Characterization Including Uncertainty Estimates to 1.0 THz"This dataset contains the calibrated scattering parameters (S-parameters) of a thru that was...
- commented lines start with a % sign. data lines are space delimited.
- there are two sections. 1st section is the measured data and 2nd section is the simulated data. commented lines start with a % sign. data lines are space delimited.
- there are two sections. 1st section is the measured data and 2nd section is the simulated data. commented lines start with a % sign. data lines are space delimited.
- there are two sections. 1st section is the measured data and 2nd section is the simulated data. commented lines start with a % sign. data lines are space delimited.
- there are two sections. 1st section is the measured data and 2nd section is the simulated data. commented lines start with a % sign. data lines are space delimited.
- there are two sections. 1st section is the measured data and 2nd section is the simulated data. commented lines start with a % sign. data lines are space delimited.
- +4 more
Search relevance: 95.61 | Views last month: 0 -
In this paper, we have demonstrated the importance of choosing the correct reference plane for applications such as over-the-air (OTA) modulated-signal measurements at millimeter-wave frequencies....
Search relevance: 53.50 | Views last month: 1 -
Data used to generate figures in Large-Signal-Network-Analyzer Phase Calibration on an Arbitrary Grid.
Search relevance: 52.12 | Views last month: 1 -
Abstract from manuscript:We demonstrate a glass microwave microfluidic device for determining the permittivity of a wide range of liquid chemicals from 100 MHz to 10 GHz with relatively low...
Search relevance: 49.62 | Views last month: 0 -
The enclosed dataset includes measurements of a thickness series of CoFeB thin film samples that were deposited at the NIST Magnetic Engineering Research Facility using magnetron sputtering. The...
Search relevance: 49.26 | Views last month: 0 -
Test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz - Calnet
The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p,...
Search relevance: 45.45 | Views last month: 1 -
Broadband S-parameter measurements of Parylene C microwave microfluidic devices from 100 MHz - 110 GHz. The Parylene C devices consisted of 400 nm platinum coplanar waveguides (CPW) (50 um center...
Search relevance: 39.38 | Views last month: 0 -
Data published in paper "Microstrip and Grounded CPW Calibration Kit Comparison for On-Wafer Transistor Characterization from 220 GHz to 325 GHz"We investigated the effect of two uncertainty...
- comments lines have a % in front of them, data is space delimited.
- commented lines start with a % sign. data lines are space delimited. text broken up into three sections. one for the histogram, one for the gaussian curve, and one for the measured data
- comment lines start with a % sign. data lines are space delimited
- comment lines start with a % symbol. data lines are space delimited
- plain text descriptions of the data files. no specific formatting.
Search relevance: 39.33 | Views last month: 0